ALUCO.TEK material suppliers

|
|
Brief Introduction |
Our fire-resist aluminum composite panel is made of fireproof plastic core with two layers of aluminum shees, it is one kind of new decorative material. Because of addition of fireproof element, its fireproof feature can reach Class B1 grade with the test of GB8624, hard to be fired. It is green material, as there is no harmful gas during burning. |
|
Structure & Specification |
|
|
Fire-resist ACP safety degree is based on GB8624-1997 "Classification of Building Materials". Aluco.Tek fire-resistance ACP can be achieved Hard-buring Class B1 or No-combustion Class A .
 |
Thickness: 3-6mm, recommend: 4mm
Width: 1000-1575mm, recommend: 1220mm, 1250mm and 1500mm
Length: maximum 5800mm, recommend: 2440mm, 3050mm, and 4050mm
Aluminum thickness:0.3mm to 0.5mm
|
|
|
The level and combustion properties of names. |
|
Degree |
Item |
Degree |
Item |
A |
No-Combustion |
B2 |
Combustion |
B1 |
Hard- Combustion |
B3 |
Combustible |
Degree |
Material |
The combustion performance indicators |
No-Combustion |
Class A Material |
According GB/T8625 test, the average length of the remaining ≤ 35 cm (including any residual specimen length> 20 cm) for each test and the average flue gas temperature peak ≤ 125 ° C, no specimen back burner the scene;
According GB/8627 test, their smoke density levels (SDR) ≤ 15;
According to GB/T14002 and GB/T14403 test, its calorific value ≤ 4.2 MJ / kg, and the specimen thermal emission per unit area ≤ 16.8 MJ/m2; toxic materials combustion flue gas of the entire non-lethal concentration of ≥ 25 mg / L |
Hard Combustion |
Class B1 Material |
According GB/T8626 test, its combustion properties should be met GB/T8626, and does not allow any dropping of combustion burn the filter paper;
According GB/T8625 test, the average of each specimen remaining length ≥ 15 cm (including any residual specimen length> 0 cm), and the average peak temperature of gas ≤ 200 ℃ in each test.
According GB/T8627 test, their smoke density levels (SOR) ≤ 75 |
|
|
The contrast of fire-resist performance in different countries |
|
Standard
Burning Degree |
China |
Germany |
U.S.A |
France |
U.K |
Japan |
Russia |
GB/T8627 |
DIN 4102 |
ASTM E84 |
BS 476 |
NFF 16-101 |
JIS K6911 |
30244-94 |
Few |
A |
A1,A2 |
NC |
0 |
MO |
1 |
T1 |
Minor |
B1 |
B1 |
A |
1 |
M1,M2 |
2 |
T2 |
Normal |
B2 |
B2 |
B,C |
2.3 |
M3 |
3 |
T3 |
Serious |
B3 |
B3 |
|
4 |
M4,M5 |
- |
- |
|
|
Fire-resist |
The outer aluminium sheet and inner fire-resist polyethylene makes the panle has a excellent performance. The fire-resist panel meet the GB8624 B1 standard and is fire retardant stratified, smoke less and no harmful gas. |
High Strengeh |
The fire-resist ACP use high quality aluminum with greatly enhanced strength, ensure the performance of wind-pressure resistance, shockproof, and anti-impact. |
Smooth Surface |
The fire-resist ACP provide superior and smooth surface, satisfying the modern building with perfect appearance. |
Easy Processing |
ACP is easy to cut, slot, punch, bend into circular, rectangular and other shapes, also can be designed to various modeling according to your ideas. |
Exertion Design |
The fire-resist ACP has series of glossy and shape to meet the designer great originality, achieve perfect results. |
Class B1 Burning Test Report |
|
No. |
Text Item |
Test Method |
Technical Index |
Result |
1 |
Minimum remaining length of combustion, mm |
GB/T8625-88 |
>0 |
486 |
2 |
Average remaining length of combustion, mm |
GB/T8625-88 |
≥150 |
163 |
3 |
Smoke temperature ℃ |
GB/T8625-88 |
≤200 |
78 |
4 |
Height of fire, mm |
GB/T8625-88 |
≤150 |
10 |
5 |
Grade of smoke density |
GB/T8627-88 |
<75 |
9 |
|
|

architectural
.jpg)
large range of colors pvdf

brushed finish
|